EI
vs Toroid
Now that you’ve been bored by the background (see previous
Bryston Newsletter
–
Volume 8 Issue 4) let’s get to the main event: drop the
gloves and compare transformers.
Core
Geometry
Here we can more clearly see why the EI is so named.
Es and I’s are alternately stacked layer upon layer create
the core. The density of steel to air provides a stacking factor.
Tightly packed cores have a higher stacking factor and better performance
on all fronts. EI cores have typical stacking factors of .90.
The toroid is a tape-wound core
it is wound from a continuous strip of thin silicon steel, under
pressure. The start and finish are spot welded, and the core is
annealed to relax the molecular structure. The typical stacking
factor of a toroid is .98.
Thinner material more solidly packed
plus annealing makes toroidal cores far superior to EI cores. Score:
Donuts 2 (Two, one each for better stacking factor and thinner material),
EIs 0.
Gaps
Gaps are bad in most power transformer applications. Tape-wound
toroidal cores don’t have any (although they can be introduced
as required for inductors and other special applications). Air gaps
reduce permeability and increase stray magnetic fields. At every
layer of an EI transformers core three areas of unavoidable gap
exist. The areas occur at the junctions between each “leg”
of the E and the I. Score: Donuts 5 (Score three; one for each EI
gap), EIs 0
Grain
Direction
Grain direction in cores is important because it focuses magnetic
energy. All tape-wound toroidal cores using grain-oriented silicon
steel have 100% of the grains in one direction. EI transformers
use grain oriented or non-oriented silicon steel. Non-oriented silicon
steel is cheaper and a much lower performer (permeability and stray
magnetics) than the grain-oriented variety. Score: Donuts 6 (For
better grain direction), EIs 0
Flux
Flow
Once windings excite a core, magnetic energy, or flux, flow in a
closed circuit. The diagram at right shows the respective patterns
for EI and toroidal cores. Note the tight corners, unused areas
and obstacles (holes and gaps) in the flux path of the EI. Score:
Donuts 7 (Cleaner flux flow pattern), EIs 0
Grain
with Flux
Here’s the crux of the matter. Overlaying the flux pattern
with the grain direction clearly shows why toroids are so much better
than EIs. It’s really hard to imagine how flux can find its
way in an EI, going against the grain so often and having to jump
gaps and squeeze around holes. The core of a toroidal transformer
has a grain structure 100% in-line with the flux flow. An EI has
about 1/3rd of its core grain structure in the wrong direction.
Score: Donuts 8 (Near perfect alignment of grain structure and flux
field), EIs 0
Core
utilization
Windings completely cover the toroidal core; the EI has about 1/3rd
covered. An EI transformer’s poor core utilization is a major
contributor to its low efficiency, high stray magnetic fields and
audible hum. Score: Donuts 9 (About 3 times the core utilization),
EIs 0
Noise
Audible noise, or transformer hum, is expected from
EI transformers. To some, the EI hum is like an audible on light.
Even under generally good line input conditions, EI transformers
hum, while toroidal transformers are virtually silent.
So many things contribute to this
hum in EIs: Their thicker core laminations chatter amongst themselves
because the stacking factor is poor; Gaps between Es and I’s
and gaps between the core and bobbin (the thing that holds the windings)
add to the noise. The necessary vacuum varnishing can’t sufficiently
dampen the hum.
To reduce the noise when EIs are
installed into equipment, elaborate sub-chassis and shock mounting
are sometimes employed.
Toroids have little to contribute
audibly. There core is much more tightly packed and of thinner material.
There is no bobbin. Insulation and wire are tightly wound directly
and completely over the core (the source of noise in transformers).
Because a toroidal core can operate at higher permeability, it can
easily be wound with higher numbers of turns to reduce to possibility
of saturation, while still retaining all of its benefits over EI
transformers. Score: Donuts 10 (Quieter under normal conditions),
EIs 0
Efficiency
Transformer inefficiencies are made of copper losses and iron losses.
Copper losses refer to the windings (wire) and Iron losses refer
to the core. Losses through the windings are almost completely from
resistance and the product is heat. Core losses are from eddy currents,
which are electrical and produce heat, and the physical movement,
known as magneto striction, that usually creates noise.
Toroidal transformers have higher
permeability, gapless cores with thinner laminations and better
grain geometry. This allows them to have fewer turns for a given
voltage than EI transformers.
Fewer turns at a given gauge of
wire means lower resistance and less heat. The thinner laminations
on a toroid mean much lower eddy current loss and under normal operation
conditions, toroids do not convert energy into core noise, like
EIs. Less loss of all kinds adds up to greater efficiency for toroids.
Score: Donuts 12 (Score 2. More efficient in both core and winding
losses.), EIs 0
Performance
Lower copper loss means better regulation. (Regulation is the difference
between loaded and unloaded output voltages.) Lower overall losses
make for a cooler product, less thermal stress on surrounding components
and longer transformer and product life. Score: Donuts 14 (Score
two. Better regulation and cooler operating.), EIs 0
Size
With other specifications approximately equal, a toroidal transformer
can be less than the size and weight of an EI transformer. The core
is smaller because it is higher in permeability, so higher in flux
density. Because of these things, there is less copper. Less material:
smaller size and lower weight. Score: Donuts 16 (Score two. Smaller
and lighter.), EIs 0
DC
Offset
All power transformers work with AC. DC (direct current) cannot
make the flux changes required to sustain a transferable magnetic
field. Under normal conditions DC does not exist on power lines.
However, because of nasty things like cheap lighting dimmer switches,
sometimes a small DC component can occur on an AC line. Because
toroidal cores are so efficient, they sustain magnetic flux easily.
DC offset on an AC line will eventually cause the toroidal core
to go into saturation by continually driving the core into one direction.
This sounds bad both literally and figuratively. But, it’s
rare and there are easy solutions. An EI transformer core has unavoidable
gaps. These gaps are generally bad, both for stray magnetics and
for overall efficiency. But, they do help here in a passive way.
An EI core can’t sustain a magnetic field for long and any
additional flux is sprayed out of it’s many gaps. So, in the
rare cases of DC offset, EIs can distribute the additional flux
into surrounding circuits. Toroids can be designed to take DC offset.
This is usually only necessary for extreme applications, like interruptible
power supplies.
Another option is to add a simple
DC blocking circuit on the primary side of the toroid. A few diodes
and a couple of capacitors easily handle the small amount of DC
that rarely gets onto AC lines. Many audio companies using toroidal
transformers employ these simple circuits to enjoy the overall benefits
of toroids. Score: Donuts 16, EIs 1 (Really shouldn’t count,
but we don’t want to embarrass.)
Off Load Losses
Also as a direct result of core efficiency, toroids consume about
1/10th the energy of EI transformer when no load is present on the
secondary. For many applications, where the equipment is on but
often not operating, energy savings can be substantial. But even
if this direct specification is not capitalized, it is at least
a very good indication of an extremely effective core. Score: Donuts
17 (Much lower quiescent current draw.), EIs 1
Stray
Fields
EI transformers emit about 10 times as much energy in stray magnetic
fields compared to toroids. These emissions can cause steel chassis
to rattle and video screen images to jiggle or get grainy. They
add noise to audio signals and any other signals in their proximity.
Gaps and poor core utilization are the culprits. Toroids don’t
have gaps and EIs can’t avoid them. A Toroid’s windings
cover 100% of the core while an EI’s only covers a third.
Score: Donuts 18 (For non-interference with surrounding equipment.),
EIs 1
In
Rush
Toroidal cores stay magnetized once turned off. This
again testifies to their efficiency, but if the transformer is turned
back on during the same positive AC cycle, higher currents are drawn
from the line. This condition is called in-rush and it only occurs
if the conditions are just right and only for a maximum
cycle (about 0.008 seconds). It is also not dangerous to the transformer
or equipment and is easily rectified in the product - in most cases
only a slow blow fuse is required. For higher power applications
an NTC (negative temperature coefficient) resistor may be used.
Toroids can also be designed to lower in-rush levels depending on
the application.
Again, inadvertently, due to the
gaps in EIs, a stand-alone non-optimized toroidal transformer will
not perform as well as the EI in this narrow category. But, with
proper fusing, or modest protection, or special attention at the
time of design, in-rush is not an issue for a toroid. Score: Donuts
18, EIs 2 (A second arguable goal.)
Conclusion
Toroids make better pucks than EIs. There is just no way
a clunky sharp-edged hulk of an EI is going to slip as silkily down
the ice as a nice toroid. Okay, with DC offset or in-rush, unprotected
toroids perform marginally lower in these easily avoidable situations.
But, let’s put it in perspective. In a properly engineered
application, there are always trades and in the balance toroids
are the hands-down performance winners. In equipment, and everywhere
else, toroids are simply better than EIs.
Remember the ideal transformer?
It’s 100% efficient, no core losses, no winding losses, 0%
load regulation, and no radiation of heat, or audible noise or magnetic
field. No transformer’s ideal, but the toroid is miles ahead
of the competition. It is the closest to 100% efficient because
its core losses are negligible, so there are fewer turns per volt,
which means shorter windings and less resistance. Thinner laminations,
aligned grain and flux patterns and no gaps are what make the core
clearly better and keep the radiation and noise down. Less resistance
in the windings means less energy loss to heat and far better regulation.
There is no mystique only fact, toroids are better than EIs. Toroids
are quiet and toroids are cool. Toroids are donuts and everybody
deserves donuts. And your equipment deserves the ideal transformer,
a toroid.
|